Room Humidity Transmitters 5% or 3% indicates
Features
Room Humidity Transmitters
· Indoor Humidity measurement.
· Wide range of temperature probes
· 0-10V or 4-20mA measuring signals
· Compact size and modern design
Applications
· Indoor humidity measurement for comfort control
Humidity Tansmitter
The transmitter measures the humidity by the honeywell humidity sensor HIH-3610. The transmitter analog output may be be 0-10V or 4-20mA. And the transmitter include a noise filter.the power suply is large range VDC18V----VDC30V.The humidity transmitter measurement range is 5%-95%.
Ordering
Ordering number:RH-5U-R or RH-5U-R-T
-5 indicates the humidity transmitter accuracy is 5%; -3 indicates 3%, -2 indicates 2%.
-U indicates the humiditt transmitter signal out is 4-20mA or 0-10V optional.
-T indicates the humidity transmitter integration with temperature signal out.
For example:RH-5U-R-T
The room humidity and temperature transmitter signal out is 4-20mA or 0-10V optional .
Installation
Mount the humidity transmitter on a flat interior wall of the room to be controlled. Do avoid obstructions such as shelves, curtains and recesses. Do not place near heat sources, draft channels. Do not expose to direct sunlight.
· When installing the unit, fix the base plate first, connect the electrical connections then hook on the cover and secure it.
· The end of the conduit at the sensor must be sealed to prevent false measurements due to draughts through the conduit.
· Connect the wires according to the wiring diagram to the measuring circuit in the cover:
o If only humidity, the transmitter need three terminal connections,DC24V,Ground and humidity signal out.
o If humidity and temperature, the transmitter need four terminal connections, DC24V,Ground , humidity signal out and temperature signal out .
o The connection signal cable should be shield wires.
Technical Specification
Power suply | Option voltage | VDC18V---VDC30V |
Power Cunsumption | Max 2 VA | |
Signal out | signal | 4-20mA or 0-10V |
Humudity accuracy | 5% | |
Humudity range | 0%-100% | |
Temperature accuracy | 0.5 degree C | |
Temperature range | 0-50 degree C | |
Sensing element | Capacitive Element: Range Accuracy | 5%---95% 2% |
Connection | Connection Terminals | 2.5 mm2 |
Environment | OperationClimatic ConditionsTemperatureHumidity | To IEC 721-3-3class 3 K5-4070°C<95% r.h. |
Transport & StorageClimatic ConditionsTemperatureHumidityMechanical Conditions | To IEC 721-3-2 and IEC 721-3-1class 3 K3 and class 1 K3-4080°C<95% r.h.class 2M2 | |
Standards | conform according to EMC Standard 89/336/EECEMEI Standard 73/23/EEC | EN 61 000-6-1/ EN 61 000-6-3 |
Automatic electrical controls for household and similar use Special requirement on temperature dependent controls | EN 60 730 1 EN 60 730 2 - 9 | |
Pollution Class | Normal acc. To EN 60 730,RoHS compliant | |
Degree of Protection | IP56 to EN 60 529 | |
Safety Class | III (IEC 60536) | |
Housing Materials | Cover & Mounting Plate | Fire proof ABS plastic |
General | Dimensions [mm] | Cover: 42 x 112 x 88 (H x W x D) probe: ø 10 x 200 (Diameter x L) |
Weight (including package) | 135g |
Room Humidity Transmitters 5% or 3% indicates